| Small Pipeline Sizes: Instrument, Utility and General Service Lines |
| DN15 | 1/2 in | 15 | 0.95 | 1.91 | Use for very low flow services where the connected pipe and fittings have the same nominal size. | Check minimum actuator torque, installation space and the available power supply. |
| DN20 | 3/4 in | 20 | 1.70 | 3.39 | Suitable for small utility, heating and general process branches. | Confirm the valve operating time and whether a manual override is required. |
| DN25 | 1 in | 25 | 2.65 | 5.30 | Match the bore to the piping system rather than selecting solely by actuator connection size. | Verify close-off torque at the maximum differential pressure. |
| DN32 | 1 1/4 in | 32 | 4.34 | 8.69 | Appropriate for compact distribution and low-capacity process lines. | Check control wiring, limit switches and the required fail position. |
| DN40 | 1 1/2 in | 40 | 6.79 | 13.57 | Use when a low pressure drop and unobstructed flow path are important. | Confirm the valve-end connection standard and actuator mounting arrangement. |
| DN50 | 2 in | 50 | 10.60 | 21.21 | A common branch-line size; full-bore passage helps reduce losses when fully open. | Allow room for actuator removal, cable entry and maintenance access. |
| DN65 | 2 1/2 in | 65 | 17.92 | 35.83 | Select where the calculated flow falls between common DN50 and DN80 requirements. | Review the actuator duty rating for the expected number of operating cycles. |
| DN80 | 3 in | 80 | 27.14 | 54.28 | Suitable for medium-capacity water, air and process services. | Check pipeline support because the actuator increases the valve assembly weight. |
| Medium Pipeline Sizes: Plant Distribution and Process Systems |
| DN100 | 4 in | 100 | 42.41 | 84.82 | Choose for medium flow duties when the calculated pressure loss supports a full-bore gate valve. | Verify torque requirements at both clean and potentially fouled operating conditions. |
| DN125 | 5 in | 125 | 66.27 | 132.53 | Useful for larger distribution branches and moderate process flow rates. | Confirm actuator output, stem thrust limits and electrical enclosure suitability. |
| DN150 | 6 in | 150 | 95.43 | 190.84 | Common for plant headers; maintain a full-bore path where pigging or solids passage is required. | Consider gearbox ratio, emergency operation and local position indication. |
| DN200 | 8 in | 200 | 169.65 | 339.29 | Suitable for high-capacity lines when the valve is primarily used for isolation. | Check structural loads, flange alignment and actuator starting torque. |
| DN250 | 10 in | 250 | 265.07 | 530.13 | Use after confirming the required flow, pressure class and acceptable system velocity. | Review power consumption, travel time and the need for torque or thrust monitoring. |
| DN300 | 12 in | 300 | 381.70 | 763.38 | Appropriate for major process headers and water-distribution mains. | Provide adequate support and verify that the actuator can operate under worst-case pressure. |
| DN350 | 14 in | 350 | 519.57 | 1,039.14 | Select where a larger bore is needed to limit velocity and pressure loss. | Check installation orientation, stem extension requirements and access for servicing. |
| DN400 | 16 in | 400 | 678.58 | 1,357.17 | Use for large headers where isolation reliability is more important than throttling control. | Confirm actuator mounting strength, backup power and end-of-travel protection. |
| Large Pipeline Sizes: Main Headers, Waterworks and Industrial Networks |
| DN450 | 18 in | 450 | 858.83 | 1,717.65 | Use for high-capacity mains after a hydraulic calculation confirms the required bore. | Evaluate actuator inertia, operating time, foundation loads and cable protection. |
| DN500 | 20 in | 500 | 1,060.29 | 2,120.58 | Full-bore design is beneficial where minimizing permanent pressure loss is a priority. | Specify reliable torque limiting and verify the electrical supply during peak load. |
| DN600 | 24 in | 600 | 1,526.81 | 3,053.63 | Suitable for large water, utility and process transmission lines. | Check valve mass, pipe supports, actuator enclosure rating and emergency shutdown logic. |
| DN700 | 28 in | 700 | 2,078.16 | 4,156.32 | Select when capacity and low flow resistance justify the larger valve diameter. | Confirm stem load, gearbox capacity, travel limits and site lifting provisions. |
| DN750 | 30 in | 750 | 2,385.65 | 4,771.30 | Use for large-diameter distribution networks with carefully reviewed hydraulic conditions. | Check actuator duty cycle, anti-condensation protection and local control accessibility. |
| DN800 | 32 in | 800 | 2,714.34 | 5,428.68 | Appropriate for major headers where a full-bore passage helps reduce operational losses. | Review structural support, flange loads, actuator alignment and maintenance clearance. |
| DN900 | 36 in | 900 | 3,435.33 | 6,870.66 | Choose only after confirming pipeline capacity, transient effects and allowable velocity. | Assess closing time to limit water hammer and coordinate operation with the control system. |
| DN1000 | 40 in | 1,000 | 4,241.15 | 8,482.30 | Suitable for very large mains where reliable isolation and low open-valve resistance are required. | Confirm actuator thrust, backup operation, position feedback and foundation design. |
| DN1200 | 48 in | 1,200 | 6,107.26 | 12,214.53 | Use for high-capacity transmission lines after a complete hydraulic and mechanical review. | Consider controlled closing, surge protection, lifting equipment and full access for inspection. |